Midterm Results After Coated and Uncoated TKA: A Randomized Controlled Study

Franziska Beyer; Cornelia Lützner; Stephan Kirschner, MD; Jörg Lützner, MD

Abstract

Patients undergoing total knee arthroplasty (TKA) who have hypersensitivity to metals usually receive hypoallergenic TKA implants. Coating of a standard implant is a common solution. Although in vitro tests have demonstrated reduction in polyethylene wear for these coatings, it is unknown whether these costly implants have a clinical benefit for patients. One hundred twenty patients undergoing TKA were randomly assigned to receive a novel 7-layer-coating implant or a standard TKA implant. One revision occurred in the standard group, resulting in a calculated 5-year survival of 100% in the coated group and 98.1% in the standard group. The Oxford Knee Score improved substantially in both groups from a mean of 21.6 points preoperatively in the coated group and 21.9 points in the standard group to 39.2 points and 39.2 points, respectively. The current authors observed no adverse effects with the new coating during midterm follow-up. However, longer follow-up time is needed to evaluate possible advantages of this coating. [Orthopedics. 2016; 39(3):S13–S17.]

Abstract

Patients undergoing total knee arthroplasty (TKA) who have hypersensitivity to metals usually receive hypoallergenic TKA implants. Coating of a standard implant is a common solution. Although in vitro tests have demonstrated reduction in polyethylene wear for these coatings, it is unknown whether these costly implants have a clinical benefit for patients. One hundred twenty patients undergoing TKA were randomly assigned to receive a novel 7-layer-coating implant or a standard TKA implant. One revision occurred in the standard group, resulting in a calculated 5-year survival of 100% in the coated group and 98.1% in the standard group. The Oxford Knee Score improved substantially in both groups from a mean of 21.6 points preoperatively in the coated group and 21.9 points in the standard group to 39.2 points and 39.2 points, respectively. The current authors observed no adverse effects with the new coating during midterm follow-up. However, longer follow-up time is needed to evaluate possible advantages of this coating. [Orthopedics. 2016; 39(3):S13–S17.]

Total knee arthroplasty (TKA) is an effective treatment option for advanced osteoarthritis of the knee.1 Although patients clearly benefit from joint replacement in terms of mobility and quality of life, implant-specific local and systemic adverse effects, due to corrosion, wear, and release of metal ions, still constitute a matter of concern.2,3 The release of metallo-organic complexes may trigger local and systemic toxic effects, activate the immune system,4 induce a delayed-type hypersensitivity reaction5–7 and may even contribute to the pathophysiological mechanism of aseptic loosening.2

Elevated metal ion concentrations8 and increased rates of metal hypersensitivities have been reported6,9,10 after TKA. However, the influence of these findings on outcome after TKA remains unclear.

According to guidelines,11 patients with hypersensitivity to implant materials usually receive hypoallergenic implants. Reduction of metal ion release by coating of a standard implant is a common solution. In vitro biomechanical tests demonstrated a reduction of metal ion release and superior tribological characteristics of these coated TKA implants and thus, less polyethylene wear particles.12–15 However, it is unknown whether these costly implants add a patient-relevant value in vivo with regard to hypersensitivity reactions, metalion release and improved long-term results by reduced wear. There have even been reports about less favorable clinical results16,17 and blistering of the coating caused by differences in stiffness between implant and coating.18 A novel 7-layer coating system has been developed to solve these problems by a gradient change in stiffness between the implant body and the final coating layer.15

The current study was initiated to investigate this novel coating system in comparison to the standard implant. This is a follow-up report of an earlier published study,19 comparing the midterm outcomes between coated and uncoated TKA.

Materials and Methods

After institutional review board approval and informed consent of each patient, a total of 120 patients without known hypersensitivities against implant materials were randomly assigned to receive a coated TKA implant (n=61) or an uncoated standard TKA implant (n=59). Both implants were similar except for the coating. Before surgery, 3 months after surgery and yearly thereafter, the Oxford Knee Score (OKS, maximum 48 points) was filled in. Nonresponders were contacted by phone. Adverse events were assessed at all visits.

A total of 111 patients were available for the last follow-up at 4 years, 58 in the coated group and 53 in the standard group (Figure 1). Three patients had died, 1 patient (standard group) underwent revision TKA after 34 months because of medial instability and chronic patellar dislocation, 3 patients refused to continue participation, and 2 patients were unable to respond because of severe illness unrelated to the TKA.


Flowchart of study patients. Abbreviation: TKA, total knee arthroplasty.

Figure 1.

Flowchart of study patients. Abbreviation: TKA, total knee arthroplasty.

Implant

The Columbus Knee System (B. Braun, Aesculap, Tuttlingen, Germany) is a CE-certified TKA, and all metal components consist of a CoCrMoalloy (ISO 5832-4) containing 58.65% to 64.65% cobalt, 26.5% to 30.0% chromium, 4.5% to 7.0% molybdenum, and less than 1.0% nickel. A multilayer coating system (Advanced Surface, B. Braun) was developed to reduce ion release and includes a thin adhesive chromium layer, 5 alternating intermediate chromium nitride-chromium carbonitride (CrN-CrCN) layers, and a final shielding layer of zirconium nitride (ZrN). This 7-layer coating system was applied on the CoCr-Mo knee implants using a physical vapor deposition method with a total thickness of about 4 µm.15

Operative Procedure

A coated or uncoated unconstrained cemented TKA with a fixed polyethylene insert was implanted without patellar resurfacing in all patients. All operations were performed with a tourniquet after a single 1.5-g dose of antibiotics (cefuroxime), using a medial parapatellar approach and a conventional measured resection technique. Full weight bearing was allowed postoperatively, and mobilization began from postoperative day 1.

Statistical Analysis

Data description was based on means and standard deviation for continuous variables and absolute and relative frequencies for categorical variables. Comparisons between treatment groups were done by paired t-test for continuous variables and chi-square test for categorical variables. Implant survival was analyzed using the Kaplan-Meier function, and differences between groups were compared using the log-rank test. Significance level was set at P<.05. The software SPSS for Windows version 21.0; (IBM Corp, Armonk, New York) was used for data analysis.

Results

The 2 groups were not different with regard to preoperative and perioperative data, such as gender, age, body mass index, length of hospital stay, cut-sew-time and comorbidities (Table).


Preoperative Data for the Remaining 111 Patients

Table:

Preoperative Data for the Remaining 111 Patients

With regard to implant survival both groups demonstrated excellent midterm results with only 1 revision in the standard TKA group (Figure 2). There was no significant difference between both groups (P=.296).


Kaplan-Meier Survival for coated and standard total knee arthroplasty (TKA).

Figure 2.

Kaplan-Meier Survival for coated and standard total knee arthroplasty (TKA).

Adverse Events

Two patients with coated TKA implants underwent reoperations without implant revision because of hematoma shortly after surgery.

Four patients with standard TKA implants underwent reoperations without implant revision: 1 wound dehiscence after a fall, 1 deep infection treated with debridement and irrigation and inlay exchange 7 months after surgery, 1 open arthrolysis after failed manipulation under anaesthesia 32 months after surgery, and 1 secondary patellar replacement 34 months after surgery.

Patient-Reported Outcome

The OKS improved substantially in both groups from 21.6 points (SD, 6.2) preoperatively to 39.5 points (SD, 7.8) 4 years after surgery in the coated group and from 21.9 points (SD, 7.6) to 39.2 points (SD, 7.9) in the standard group, respectively. Over the course of the successive follow-ups a steady improvement was realized until 2 years after surgery. The subscores demonstrated a more pronounced improvement in the OKS pain component (coated TKA 108%, standard TKA 100%) and less but still substantial improvement in the OKS functional component (coated TKA 56%, standard TKA 54%; Figure 3).


Oxford Knee Score Pain and Function Element (each maximum 100 points) given as mean. Abbreviation: TKA, total knee arthroplasty.

Figure 3.

Oxford Knee Score Pain and Function Element (each maximum 100 points) given as mean. Abbreviation: TKA, total knee arthroplasty.

Discussion

With a growing number of TKAs20,21 and a high prevalence of contact allergies to metals,22 there is a need for hypoallergenic implants. Although correlation between hypersensitivities diagnosed by epicutaneous skin testing and deep-tissue hypersensitivities is still a matter of debate, guidelines recommend the use of alternative implant materials in patients with a metal hypersensitivity.11 Ceramic femoral components can be used,23,24 but these implants are expensive, and their application is more demanding.25,26 Therefore, in most patients with a metal hypersensitivity, coated standard implants are used. In addition to demonstrating reduction of metal ion release, these coatings demonstrated superior abrasive properties and reduction of polyethylene wear.12,27–29 However, there have been reports about less favorable clinical results.16,17 Blistering of the coating caused by differences in stiffness between implant and coating has been reported.18,30,31 Therefore, it is not known whether these costly implants are beneficial for patients.

In this study, midterm results demonstrated significant functional improvement in both groups comparable to literature results of TKA.32 Only few studies comparing coated and standard implants could not demonstrate better results for coated TKA.17,33,34

Survival was excellent in both groups, with a calculated 5-year-survival of 100% in the coated and 98.1% in the standard TKA group, respectively. In the National Joint Registry,32 the cumulative risk of revision was 2.15% after 5 years for cemented TKA, and 3.7% for TKA in patients with osteoarthritis in the Australian National Joint Replacement Registry.35 Although the current authors did not observe any problems during midterm follow-up with the novel coating, longer term results are necessary to evaluate possible advantages such as reduced polyethylene wear.

This is, to the knowledge of the authors, the largest series comparing coated and uncoated TKA in a randomized controlled setting. Limitations include the exclusion of patients with a history of metal hypersensitivity, and therefore, the target population for coated implants. According to guidelines, standard patients with a history of metal hypersensitivity should receive a coated implant and therefore could not be randomized.

In conclusion, the current authors observed no problems with the new coating during midterm follow-up and no differences between both groups with regard to implant survival and patient-reported outcome.

References

  1. Carr AJ, Robertsson O, Graves S, et al. Knee replacement. Lancet. 2012; 379(9823):1331–1340. doi:10.1016/S0140-6736(11)60752-6 [CrossRef]
  2. Cadosch D, Chan E, Gautschi OP, Filgueira L. Metal is not inert: role of metal ions released by biocorrosion in aseptic loosening--current concepts. J Biomed Mater Res A. 2009; 91(4):1252–1262. doi:10.1002/jbm.a.32625 [CrossRef]
  3. Tharani R, Dorey FJ, Schmalzried TP. The risk of cancer following total hip or knee arthroplasty. J Bone Joint Surg Am. 2001; 83-A(5):774–780.
  4. Whittingham-Jones PM, Dunstan E, Altaf H, Cannon SR, Revell PA, Briggs TW. Immune responses in patients with metal-on-metal hip articulations: a long-term followup. J Arthroplasty. 2008; 23(8):1212–1218. doi:10.1016/j.arth.2007.10.015 [CrossRef]
  5. Basko-Plluska JL, Thyssen JP, Schalock PC. Cutaneous and systemic hypersensitivity reactions to metallic implants. Dermatitis. 2011; 22(2):65–79.
  6. Granchi D, Cenni E, Tigani D, Trisolino G, Baldini N, Giunti A. Sensitivity to implant materials in patients with total knee arthroplasties. Biomaterials. 2008; 29(10):1494–1500. doi:10.1016/j.biomaterials.2007.11.038 [CrossRef]
  7. Niki Y, Matsumoto H, Otani T, et al. Screening for symptomatic metal sensitivity: a prospective study of 92 patients undergoing total knee arthroplasty. Biomaterials. 2005; 26(9):1019–1026. doi:10.1016/j.biomaterials.2004.03.038 [CrossRef]
  8. Luetzner J, Krummenauer F, Lengel AM, Ziegler J, Witzleb WC. Serum metal ion exposure after total knee arthroplasty. Clin Orthop Relat Res. 2007; 461:136–142.
  9. Frigerio E, Pigatto PD, Guzzi G, Altomare G. Metal sensitivity in patients with orthopaedic implants: a prospective study. Contact Dermatitis. 2011; 64(5):273–279. doi:10.1111/j.1600-0536.2011.01886.x [CrossRef]
  10. Granchi D, Cenni E, Giunti A, Baldini N. Metal hypersensitivity testing in patients undergoing joint replacement: a systematic review. J Bone Joint Surg Br. 2012; 94(8):1126–1134. doi:10.1302/0301-620X.94B8.28135 [CrossRef]
  11. Thomas P, Schuh A, Ring J, Thomsen M. Orthopedic surgical implants and allergies: joint statement by the implant allergy working group (AK 20) of the DGOOC (German association of orthopedics and orthopedic surgery), DKG (German contact dermatitis research group) and dgaki (German society for allergology and clinical immunology) [in German]. Orthopade. 2008; 37(1):75–88. doi:10.1007/s00132-007-1183-3 [CrossRef]
  12. Ezzet KA, Hermida JC, Colwell CW Jr, D‘Lima DD. Oxidized zirconium femoral components reduce polyethylene wear in a knee wear simulator. Clin Orthop Relat Res. 2004; (428):120–124. doi:10.1097/01.blo.0000148576.70780.13 [CrossRef]
  13. Spector BM, Ries MD, Bourne RB, Sauer WS, Long M, Hunter G. Wear performance of ultra-high molecular weight polyethylene on oxidized zirconium total knee femoral components. J Bone Joint Surg Am. 2001; 83 (Suppl 2 Pt 2):80–86.
  14. Tsukamoto R, Chen S, Asano T, et al. Improved wear performance with cross-linked UHMWPE and zirconia implants in knee simulation. Acta Orthop. 2006; 77(3):505–511. doi:10.1080/17453670610046479 [CrossRef]
  15. Reich J, Hovy L, Lindenmaier HL, et al. Preclinical evaluation of coated knee implants for allergic patients [in German]. Orthopade. 2010; 39(5):495–502. doi:10.1007/s00132-009-1581-9 [CrossRef]
  16. Australian Orthopaedic Association. National Joint Replacement Registry. Annual Report. Adelaide:AOA; 2008; 164–165.
  17. Gobel F, Ulbricht S, Hein W, Bernstein A. Radiological mid-term results of total knee arthroplasty with femoral components of different materials [in German]. Z Orthop Un-fall. 2008; 146(2):194–199.
  18. van Hove RP, Sierevelt IN, van Royen BJ, Nolte PA. Titanium-nitride coating of orthopaedic implants: a review of the literature. Biomed Res Int. 2015; 2015:485975. doi:10.1155/2015/485975 [CrossRef]
  19. Lützner J, Hartmann A, Dinnebier G, Spornraft-Ragaller P, Hamann C, Kirschner S. Metal hypersensitivity and metal ion levels in patients with coated or uncoated total knee arthroplasty: a randomised controlled study. Int Orthop. 2013; 37(10):1925–1931. doi:10.1007/s00264-013-2010-6 [CrossRef]
  20. Kim SH, Gaiser S, Meehan JP. Epidemiology of primary hip and knee arthroplasties in Germany: 2004 to 2008. J Arthroplasty. 2012; 27(10):1777–1782. doi:10.1016/j.arth.2012.06.017 [CrossRef]
  21. Losina E, Thornhill TS, Rome BN, Wright J, Katz JN. The dramatic increase in total knee replacement utilization rates in the United States cannot be fully explained by growth in population size and the obesity epidemic. J Bone Joint Surg Am. 2012; 94(3):201–207. doi:10.2106/JBJS.J.01958 [CrossRef]
  22. Schafer T, Bohler E, Ruhdorfer S, et al. Epidemiology of contact allergy in adults. Allergy. 2001; 56(12):1192–1196. doi:10.1034/j.1398-9995.2001.00086.x [CrossRef]
  23. Bal BS, Garino J, Ries M, Oonishi H. Ceramic bearings in total knee arthroplasty. J Knee Surg. 2007; 20(4):261–270. doi:10.1055/s-0030-1248055 [CrossRef]
  24. Bergschmidt P, Bader R, Ganzer D, et al. Ceramic femoral components in total knee arthroplasty: two year follow-up results of an international prospective multi-centre study. Open Orthop J. 2012; 6:172–178. doi:10.2174/1874325001206010172 [CrossRef]
  25. Kluess D, Mittelmeier W, Bader R. Intraoperative impaction of total knee replacements: an explicit finite-element-analysis of principal stresses in ceramic vs. cobalt-chromium femoral components. Clin Biomech (Bristol, Avon). 2010; 25(10):1018–1024. doi:10.1016/j.clinbiomech.2010.08.002 [CrossRef]
  26. Kluess D, Bergschmidt P, Mueller I, Mittelmeier W, Bader R. Influence of the distal femoral resection angle on the principal stresses in ceramic total knee components. Knee. 2012; 19(6):846–850. doi:10.1016/j.knee.2012.03.014 [CrossRef]
  27. Ezzet KA, Hermida JC, Steklov N, D'Lima DL. Wear of polyethylene against oxidized zirconium femoral components effect of aggressive kinematic conditions and malalignment in total knee arthroplasty. J Arthroplasty. 2012; 27(1):116–121. doi:10.1016/j.arth.2011.06.002 [CrossRef]
  28. Oonishi H, Ueno M, Kim SC, Oonishi H, Iwamoto M, Kyomoto M. Ceramic versus cobalt-chrome femoral components; wear of polyethylene insert in total knee prosthesis. J Arthroplasty. 2009; 24(3):374–382. doi:10.1016/j.arth.2007.10.021 [CrossRef]
  29. Reich J, Thomas P, Hovy L, Lindemaier HL, Zeller R, Schwiesau J. Allergy solutions for orthopaedic knee-implants. Biomaterialien. 2007; 8(2):109–110.
  30. Galetz MC, Fleischmann EW, Konrad CH, Schuetz A, Glatzel U. Abrasion resistance of oxidized zirconium in comparison with CoCrMo and titanium nitride coatings for artificial knee joints. J Biomed Mater Res B Appl Biomater. 2010; 93(1):244–251.
  31. Raimondi MT, Pietrabissa R. The in-vivo wear performance of prosthetic femoral heads with titanium nitride coating. Biomaterials. 2000; 21(9):907–913. doi:10.1016/S0142-9612(99)00246-X [CrossRef]
  32. The National Joint Registry Editorial Board. National Joint Registry for England, Wales, Northern Ireland and the Isle of Man. 12th Annual Report. 2015.
  33. Garrett S, Jacobs N, Yates P, Smith A, Wood D. Differences in metal ion release following cobalt-chromium and oxidized zirconium total knee arthroplasty. Acta Orthop Belg. 2010; 76(4):513–520.
  34. van Hove RP, Brohet RM, van Royen BJ, Nolte PA. No clinical benefit of titanium nitride coating in cementless mobile-bearing total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2015; 23(6):1833–1840. doi:10.1007/s00167-014-3359-9 [CrossRef]
  35. Australian Orthopaedic Association. National Joint Replacement Registry. Annual Report. 2015.

Preoperative Data for the Remaining 111 Patients

Coated TKA n=58Standard TKA n=53P Value
Age at surgery, mean (SD), y66.6 (9.0)68.6 (7.9).222
Female gender (%)53.456.6.849
BMI, mean (SD), kg/m231.3 (5.3)30.5 (4.9).388
ASA (% grade 3/4)37.9%41.5%.846
Operative time, mean (SD), min86.8 (17.0)86.1 (16.2).839
Authors

The authors are from the University Center of Orthopaedics and Traumatology (FB, CL, JL), University Medicine Carl Gustav Carus Dresden, TU Dresden, Germany; and St.Vincentus-Kliniken (SK), Karlsruhe, Germany.

Ms Beyer has received grants from Aesculap, Arthrosehilfe, Mathys, Smith & Nephew, Stryker, and Zimmer. Dr C Lützner has received grants from Aesculap, Arthrosehilfe, Mathys, Smith & Nephew, Stryker, and Zimmer. Dr Kirschner has received grants from Aesculap, Arthrosehilfe, Mathys, Smith & Nephew, and Zimmer. Dr J Lützner has received grants from Aesculap, Arthrosehilfe, Mathys, Smith & Nephew, and Zimmer.

This study was supported by a research grant from Aesculap (Tuttlingen, Germany). The study protocol was registered in the US National Institutes of Health's database ( http://www.clinicaltrials.gov) registry under NCT00862511.

Correspondence should be addressed to: Franziska Beyer, University Center of Orthopaedics and Traumatology, University Medicine Carl Gustav Carus Dresden, TU Dresden, Fetscherst. 74, 01307, Dresden, Germany ( franziska.beyer@uniklinikum-dresden.de).

Received: January 21, 2016
Accepted: February 03, 2016

10.3928/01477447-20160509-10

Sign up to receive

Journal E-contents