The survivorship of total hip arthroplasty in younger patients is dependent on the wear characteristics of the bearing surfaces. Long-term results with conventional polyethylene in young patients show a high failure rate. This study assessed the long-term results of a first-generation annealed highly cross-linked polyethylene (HCLPE) in uncemented total hip arthroplasty in young, active patients. Between 1999 and 2003, 112 total hip arthroplasty procedures performed in 91 patients with an average University of California Los Angeles activity score of 8 and mean age of 53 years (range, 24–65 years) were included from a prospective database. In all patients, a 28-mm metal femoral head on annealed HCLPE (Crossfire; Stryker, Mahwah, New Jersey) was used. At minimum 10-year follow-up (11.5±0.94 years), Kaplan-Meier survivorship was 97% for all failures (1 periprosthetic infection and 1 late dislocation) and 100% for mechanical failure (no revisions for osteolysis or loosening). This study showed low revision rates for wear-related failure and superior survivorship in young, active patients. Oxidation causing failure of the locking mechanism has not been a problem with Crossfire for up to 10 years. [Orthopedics. 2016; 39(2):e225–e229.]


Abstract

The survivorship of total hip arthroplasty in younger patients is dependent on the wear characteristics of the bearing surfaces. Long-term results with conventional polyethylene in young patients show a high failure rate. This study assessed the long-term results of a first-generation annealed highly cross-linked polyethylene (HCLPE) in uncemented total hip arthroplasty in young, active patients. Between 1999 and 2003, 112 total hip arthroplasty procedures performed in 91 patients with an average University of California Los Angeles activity score of 8 and mean age of 53 years (range, 24–65 years) were included from a prospective database. In all patients, a 28-mm metal femoral head on annealed HCLPE (Crossfire; Stryker, Mahwah, New Jersey) was used. At minimum 10-year follow-up (11.5±0.94 years), Kaplan-Meier survivorship was 97% for all failures (1 periprosthetic infection and 1 late dislocation) and 100% for mechanical failure (no revisions for osteolysis or loosening). This study showed low revision rates for wear-related failure and superior survivorship in young, active patients. Oxidation causing failure of the locking mechanism has not been a problem with Crossfire for up to 10 years. [Orthopedics. 2016; 39(2):e225–e229.]


Total hip arthroplasty (THA) can relieve pain, restore function, and improve quality of life in patients with advanced arthritis of the hip.1 In recent years, the average age of patients requiring THA has steadily decreased.2,3 These younger patients have higher activity levels and longer life expectancy and therefore a higher incidence of wear-related failure requiring revision surgery.4,5

The longevity of THA in younger patients is often limited because of wear-related osteolysis and aseptic loosening.6,7 Long-term results with conventional polyethylene in young patients showed a high failure rate (up to 33% at 10 years).8–10 Hard-on-hard bearings, such as metal-on-metal and ceramic-on-ceramic bearings, and hip resurfacing have been advocated for younger patients in an attempt to reduce revisions related to wear or osteolysis.11 However, these options did not significantly increase survivorship,4 and debate about the optimal type of bearing in these young patients continues.

Since the introduction of highly cross-linked polyethylene (HCLPE) in the 1990s, there has been an increase in its use as well as significant improvement in wear reduction at the bearing surface.4,12,13 Several studies and registry reports confirmed improvement in midterm survivorship in HCLPE compared with conventional polyethylene in younger patients.2,5,14–17 To the authors' knowledge, there are no long-term reports of the clinical and radiographic results of uncemented fixation with metal-on-HCLPE bearings in young, active patients. This study assessed the minimum 10-year results of a first- generation HCLPE in young, active patients with uncemented THA.

Materials and Methods

Between January 1999 and December 2003, the senior surgeon (C.S.R.) performed more than 900 consecutive THA procedures at the authors' institution. These patients were prospectively followed at 2, 5, and 10 years. A total of 112 THA procedures in 91 young, active patients (57 men and 34 women) were included. Inclusion criteria were age 65 years or younger and University of California Los Angeles (UCLA) activity score greater than 5 at the time of surgery. Mean patient age was 53±8 years (range, 24–65 years), and mean UCLA activity score was 8±1.5 (range, 5–10). Indications for surgery included osteoarthritis in 101 hips and avascular necrosis in 11 hips. All procedures were performed with a posterolateral approach. Components were an uncemented SecurFit femoral stem (Stryker, Mahwah, New Jersey), a 28-mm cobalt-chromium femoral head, and a Trident PSL acetabular shell (Stryker) with a Crossfire HCLPE acetabular liner (Stryker).

At a minimum 10-year follow-up, 2 patients (2 hips) had died of unrelated causes and 7 patients (7 hips) were lost to follow-up despite several attempts to contact them. The final cohort consisted of 103 hips (82 patients) that were available for analysis. Clinical assessment included the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score,18 a patient-administered questionnaire score,19 the Hospital for Special Surgery hip score, and the UCLA activity score.20 Anteroposterior weight-bearing pelvic radiographs obtained 6 weeks postoperatively and at final follow-up were evaluated for fixation, changes in component position, radiolucency, malalignment, loosening, and osteolysis by 2 blinded reviewers (A.A.R., M.M.). The radiographic abduction angle and anteversion of the cup on anteroposterior pelvic radiographs were measured with EBRA software (Einzel-Bild-Roentgen-Analysis, University of Innsbruck, Austria).21

All descriptive statistics (mean, SD) and Kaplan-Meier survival analyses were performed with SPSS version 16.0 software (SPSS Inc, Chicago, Illinois). Two-tailed P values less than .05 were considered statistically significant.

Results

Mean follow-up in the final cohort was 11.5±0.94 years (range, 10–13 years). Average WOMAC score, patient-administered questionnaire score, and Hospital for Special Surgery hip score were 94, 65, and 37, respectively (Table 1). Based on patient-administered questionnaire scores, 98% of patients were satisfied with the results. Most patients were participating in 1 or more recreational sports activities at the time of final follow-up (Table 2).


Clinical Results at Final Follow-up

Table 1:

Clinical Results at Final Follow-up


Participation in Recreational Activities at Time of Final Follow-up

Table 2:

Participation in Recreational Activities at Time of Final Follow-up

Mean radiographic inclination angle and anteversion measured with EBRA were 42.8º±5º (range, 35°–52°) and 17.1º±4º (range, 13°–23°), respectively. No revisions were performed for osteolysis or loosening. Two patients underwent reoperation: 1 patient with periprosthetic infection who underwent 2-stage revision (7 years after surgery) and 1 patient with late dislocation after a major fall that required open reduction and a constrained liner (11 years postoperatively). Intraoperative examination showed no significant polyethylene wear. At final follow-up, both patients were doing well, without further complications. Kaplan-Meier survivorship was 97% for all failures and 100% for mechanical failures.

Discussion

Young, active patients with early arthritis present a challenge to surgeons when deciding on the optimal bearing surface for THA because these patients have higher levels of physical activity and longer life expectancy than older patients with more severe disability. Previous studies recommended hard-on-hard bearings, including hip resurfacing, metal-on-metal, and ceramic-on-ceramic bearings, the optimal bearing types for this group of patients. However, because of several issues with hard-on-hard bearings (ie, with a ceramic head or liner, fracture, squeaking, and stripe wear; with metal, ion toxicity and adverse tissue reaction), HCLPE has been the most commonly used bearing material in THA worldwide. This material offers durability and low wear rates, without the disadvantages of hard-on-hard bearings.21,22 Simulator studies investigating wear rates with HCLPE showed a reduction of wear by 42% to 100% compared with conventional polyethylene.1,13,22 However, few studies have reported the long-term performance of HCLPE in young, active patients (Table 3).


Published Long-term Results and Survivorship of Total Hip Arthroplasty and Hip Resurfacing in Patients Younger Than 65 Years

Table 3:

Published Long-term Results and Survivorship of Total Hip Arthroplasty and Hip Resurfacing in Patients Younger Than 65 Years

Limitations of the current study include the 7 patients who were lost to follow-up despite many attempts to contact them. However, the final radiographs in all 7 patients showed failure for fixation or wear at a minimum of 5 years postoperatively. The strengths of this study are the prospective design and the thorough clinical and radiographic analysis.

No revisions for osteolysis or loosening occurred in this cohort of young patients with high-demand activity levels who had uncemented THA with Crossfire, a first-generation annealed HCLPE. In a retrieval study of 12 polyethylenes, Currier et al23 reported reduction of mechanical properties as a result of oxidation, especially in the presence of impingement. However, similar to the findings of Kurtz et al,24 the current study found no indirect evidence of significant oxidation on radiographs, such as osteolysis or wear-related failure of the locking mechanism.

Recent concerns about the higher failure rate and local and systemic toxicity of metal ions resulted in several recalls and reduction of metal-on-metal articulations.2,25–27 The adverse tissue reaction to metal debris in metal-on-metal THA at the bearing articulation or the head-neck junction has been reported as the major cause of early failure and poor clinical results.28 As with large head metal-on-metal THA, hip resurfacing has been considered an effective intervention for young, active men who seek an alternative to THA.4,27 However, in addition to complications with metal-on-metal bearings, such as adverse local tissue reaction, there is a risk of femoral neck fracture and avascular necrosis with hip resurfacing.28,29 Daniel et al30 reported a 16% revision rate in a prospective case series of 184 patients who underwent hip resurfacing. This study reported a mean patient age of 54 years and a mean follow-up of 10.5 years.

Ceramic-on-ceramic bearings have also been used in young, active patients because of the lower wear rates and elimination of concern about metal ions. With recent advances in ceramic composites, the risk of fracture is very low (estimated rate, 1:25,000), although edge loading or impingement or technical errors regarding proper liner placement into the acetabular shell can lead to ceramic liner fractures.31 Other complications specific to ceramic bearings, such as squeaking (up to 5%), stripe wear, and fracture (up to 2%), can lead to revision and lower survivorship, and there has been a recent decline in the use of ceramic-on-ceramic bearings.14,32,33

The long-term survivorship of hip resurfacing and THA with different bearings in young, active patients has not been well defined or reported annually by various registries.2,3,5 The Australian registry report in young patients showed that the overall cumulative percentage of revision was highest for metal-on-metal bearings and hip resurfacing (18.6% and 11.2%, respectively; higher for patients 55 years and younger) and lowest for metal-on-HCLPE and ceramic-on-HCLPE bearings (5.4% and 5.6%, respectively) (Table 4).2 This is similar to the 2013 annual report of the England and Wales registry at 9 years (17.6% and 12.3% vs 4.3% and 3.0%, respectively).5 Moreover, the cumulative revision rate for THA after 12 years was 9% for patients 55 to 65 years and 11.3% for patients younger than 55 years. In the 2013 annual Swedish Hip Arthroplasty report, the revision rate for metal-on-HCLPE bearings was 0.1% at 8 years.3


Registry Results With Different Bearings in Uncemented Total Hip Arthroscopy and Hip Resurfacing

Table 4:

Registry Results With Different Bearings in Uncemented Total Hip Arthroscopy and Hip Resurfacing

The 100% survivorship at 10 years for mechanical failures of metal-on-HCLPE bearings reported in the current study is comparable to the other published results.34–37 Several studies analyzing more than 10-year follow-up of HCLPE, ceramic-on-ceramic, and hip resurfacing showed survivorship of 96% to 100%, 96% to 99%, and 88% to 95%, respectively. However, all of these reports included patients older than 65 years.38–46

Conclusion

The current study found no significant oxidation effect or polyethylene wear that would cause adverse clinical or radiographic outcomes. This study of long-term results with the use of HCLPE bearings in THA performed in young, active patients showed low revision rates for wear-related failure and superior survivorship compared with other reports.

References

  1. Kurtz SM, Gawel HA, Patel JD. History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene. Clin Orthop Relat Res. 2011; 469(8):2262–2277. doi:10.1007/s11999-011-1872-4 [CrossRef]
  2. Australian Orthopaedic Association National Joint Replacement Registry. Hip and knee arthroplasty: annual report 2013. https://aoanjrr.dmac.adelaide.edu.au/annual-reports-2013. Accessed October 2013.
  3. Swedish Joint Registry. Annual report 2013. http://myknee.se/pdf/SKAR2013_Eng.pdf. Accessed September 2013.
  4. Haidukewych GJ, Petri J. Bearing surface considerations for total hip arthroplasty in young patients. Orthop Clin North Am. 2012; 43(3):395–402. doi:10.1016/j.ocl.2012.05.008 [CrossRef]
  5. National Joint Registry for England, Wales, and Northern Ireland. 10th annual report: 2013. http://www.njrcentre.org.uk/njrcentre/Portals/0/Documents/England/Reports/10th_annual_report/NJR%2010th%20Annual%20Report%202013%20B.pdf. Accessed October 2014.
  6. Harris WH. Conquest of a worldwide human disease: particle-induced periprosthetic osteolysis. Clin Orthop Relat Res. 2004; 429:39–42. doi:10.1097/01.blo.0000149821.72760.39 [CrossRef]
  7. Laupacis A, Bourne R, Rorabeck C, et al. The effect of elective total hip replacement on health-related quality of life. J Bone Joint Surg Am. 1993; 75(11):1619–1626.
  8. Dorr LD, Kane TJ III, Conaty JP. Long-term results of cemented total hip arthroplasty in patients 45 years old or younger: a 16-year follow-up study. J Arthroplasty. 1994; 9(5):453–456. doi:10.1016/0883-5403(94)90090-6 [CrossRef]
  9. Torchia ME, Klassen RA, Bianco AJ. Total hip arthroplasty with cement in patients less than twenty years old: long-term results. J Bone Joint Surg Am. 1996; 78(7):995–1003.
  10. Burston BJ, Yates PJ, Hook S, Moulder E, Whitley E, Bannister GC. Cemented polished tapered stems in patients less than 50 years of age: a minimum 10-year follow-up. J Arthroplasty. 2010; 25(5):692–699. doi:10.1016/j.arth.2009.05.010 [CrossRef]
  11. Boyer P, Huten D, Loriaut P, Lestrat V, Jeanrot C, Massin P. Is alumina-on-alumina ceramic bearings total hip replacement the right choice in patients younger than 50 years of age? A 7- to 15-year follow-up study. Orthop Traumatol Surg Res. 2010; 96(6):616–622. doi:10.1016/j.otsr.2010.02.013 [CrossRef]
  12. Rajadhyaksha AD, Brotea C, Cheung Y, Kuhn C, Ramakrishnan R, Zelicof SB. Five-year comparative study of highly cross-linked (crossfire) and traditional polyethylene. J Arthroplasty. 2009; 24(2):161–167. doi:10.1016/j.arth.2007.09.015 [CrossRef]
  13. Jacobs CA, Christensen CP, Greenwald AS, McKellop H. Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty. J Bone Joint Surg Am. 2007; 89(12): 2779–2286. doi:10.2106/JBJS.G.00043 [CrossRef]
  14. Kim YH, Park JW, Kulkarni SS, Kim YH. A randomised prospective evaluation of ceramic-on-ceramic and ceramic-on-highly cross-linked polyethylene bearings in the same patients with primary cementless total hip arthroplasty. Int Orthop. 2013; 37(11):2131–2137. doi:10.1007/s00264-013-2036-9 [CrossRef]
  15. Kim YH, Park JW, Patel C, Kim DY. Polyethylene wear and osteolysis after cementless total hip arthroplasty with alumina-on-highly cross-linked polyethylene bearings in patients younger than thirty years of age. J Bone Joint Surg Am. 2013; 95(12):1088–1093. doi:10.2106/JBJS.L.01211 [CrossRef]
  16. Kim YH, Choi Y, Kim JS. Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis. Int Orthop. 2010; 34(8):1123–1127. doi:10.1007/s00264-009-0878-y [CrossRef]
  17. Meftah M, Klingenstein GG, Yun RJ, Ranawat AS, Ranawat CS. Long-term performance of ceramic and metal femoral heads on conventional polyethylene in young and active patients: a matched-pair analysis. J Bone Joint Surg Am. 2013; 95(13):1193–1197. doi:10.2106/JBJS.L.00432 [CrossRef]
  18. Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW. Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol. 1988; 15(12):1833–1840.
  19. Mancuso CA, Ranawat AS, Meftah M, Koob TW, Ranawat CS. Properties of the patient administered questionnaires: new scales measuring physical and psychological symptoms of hip and knee disorders. J Arthroplasty. 2012; 27(4):575–582. doi:10.1016/j.arth.2011.07.014 [CrossRef]
  20. Naal FD, Impellizzeri FM, Leunig M. Which is the best activity rating scale for patients undergoing total joint arthroplasty?Clin Orthop Relat Res. 2009; 467(4):958–965. doi:10.1007/s11999-008-0358-5 [CrossRef]
  21. Stoeckl B, Biedermann R, Auckenthaler T, Bach C, Sununu T, Nogler M. Ante- and retroversion measurements of cups by EBRA. J Bone Joint Surg Br. 2001; 83(suppl 2):179.
  22. Rohrl SM, Nivbrant B, Nilsson K. No adverse effects of submelt-annealed highly crosslinked polyethylene in cemented cups: an RSA study of 8 patients 10 years after surgery. Acta Orthop. 2012; 83(2):148–152. doi:10.3109/17453674.2011.652889 [CrossRef]
  23. Currier BH, Currier JH, Mayor MB, Lyford KA, Collier JP, Van Citters DW. Evaluation of oxidation and fatigue damage of retrieved crossfire polyethylene acetabular cups. J Bone Joint Surg Am. 2007; 89(9):2023–2029. doi:10.2106/JBJS.F.00336 [CrossRef]
  24. Kurtz SM, Austin MS, Azzam K, et al. Mechanical properties, oxidation, and clinical performance of retrieved highly cross-linked Crossfire liners after intermediate-term implantation. J Arthroplasty. 2010; 25(4):614–623. doi:10.1016/j.arth.2009.04.022 [CrossRef]
  25. US Food and Drug Administration. 2012 meeting materials of the Orthopaedic and Rehabilitation Devices Panel. http://www.fda.gov/AdvisoryCommittees/CommitteesMeetingMaterials/MedicalDevices/MedicalDevicesAdvisoryCommittee/OrthopaedicandRehabilitationDevicesPanel/ucm309184.htm. Accessed February 17, 2013.
  26. Schmalzried TP. Metal-metal bearing surfaces in hip arthroplasty. Orthopedics. 2009; 32(9):661. doi:10.3928/01477447-20090728-06 [CrossRef]
  27. Schuh R, Neumann D, Rauf R, Hofstaetter J, Boehler N, Labek G. Revision rate of Birmingham Hip Resurfacing arthroplasty: comparison of published literature and arthroplasty register data. Int Orthop. 2012; 36(7):1349–1354. doi:10.1007/s00264-012-1502-0 [CrossRef]
  28. Biant LC. Hip resurfacing or stemmed arthroplasty for young active patients?BMJ. 2012; 344:e2663. doi:10.1136/bmj.e2663 [CrossRef]
  29. McMinn DJW, Daniel J, Ziaee H, Pradhan C. Indications and results of hip resurfacing. Int Orthop. 2011; 35(2):231–237. doi:10.1007/s00264-010-1148-8 [CrossRef]
  30. Daniel J, Ziaee H, Kamali A, Pradhan C, Band T, McMinn DJ. Ten-year results of a double-heat-treated metal-on-metal hip resurfacing. J Bone Joint Surg Br. 2010; 92(1):20–27. doi:10.1302/0301-620X.92B1.21530 [CrossRef]
  31. Hamilton WG, McAuley JP, Dennis DA, Murphy JA, Blumenfeld TJ, Politi J. THA with Delta ceramic on ceramic: results of a multicenter investigational device exemption trial. Clin Orthop Relat Res. 2010; 468(2):358–366. doi:10.1007/s11999-009-1091-4 [CrossRef]
  32. Lee YK, Ha YC, Yoo JJ, Koo KH, Yoon KS, Kim HJ. Alumina-on-alumina total hip arthroplasty: a concise follow-up, at a minimum of ten years, of a previous report. J Bone Joint Surg Am. 2010; 92(8):1715–1719. doi:10.2106/JBJS.I.01019 [CrossRef]
  33. Jarrett CA, Ranawat AS, Bruzzone M, Blum YC, Rodriguez JA, Ranawat CS. The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Joint Surg Am. 2009; 91(6):1344–1349. doi:10.2106/JBJS.F.00970 [CrossRef]
  34. D'Antonio JA, Manley MT, Capello WN, et al. Five-year experience with Crossfire highly cross-linked polyethylene. Clin Orthop Relat Res. 2005; 441:143–150. doi:10.1097/00003086-200512000-00024 [CrossRef]
  35. Digas G, Herberts P, Karrholm J, et al. Cross-linked vs conventional polyethylene in bilateral hybrid THA: randomized RSA study. Trans Orthop Res Soc. 2004; 29:319.
  36. Dorr LD, Wan Z, Shahrdar C, Sirianni L, Boutary M, Yun A. Clinical performance of a Durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years. J Bone Joint Surg Am. 2005; 87(8):1816–1821. doi:10.2106/JBJS.D.01915 [CrossRef]
  37. Heisel C, Silva M, dela Rosa M, Schmalzried TP. Short-term in vivo wear of cross-linked polyethylene. J Bone Joint Surg Am. 2004; 86(4):748–751.
  38. Snir N, Kaye ID, Klifto CS, et al. 10-year follow-up wear analysis of first-generation highly crosslinked polyethylene in primary total hip arthroplasty. J Arthroplasty. 2014; 29(3):630–633. doi:10.1016/j.arth.2013.07.034 [CrossRef]
  39. Fukui K, Kaneuji A, Sugimori T, Ichiseki T, Matsumoto T. Wear comparison between conventional and highly cross-linked polyethylene against a zirconia head: a concise follow-up, at an average 10 years, of a previous report. J Arthroplasty. 2013; 28(9):1654–1658. doi:10.1016/j.arth.2012.12.020 [CrossRef]
  40. Reynolds SE, Malkani AL, Ramakrishnan R, Yakkanti MR. Wear analysis of first-generation highly cross-linked polyethylene in primary total hip arthroplasty: an average 9-year followup. J Arthroplasty. 2012; 27(6):1064–1068. doi:10.1016/j.arth.2012.01.006 [CrossRef]
  41. Vendittoli PA, Riviere C, Lavigne M, Lavoie P, Alghamdi A, Duval N. Alumina on alumina versus metal on conventional polyethylene: a randomized clinical trial with 9 to 15 years follow-up. Acta Orthop Belg. 2013, 79(2):181–190.
  42. Sugano N, Takao M, Sakai T, Nishii T, Miki H, Ohzono K. Eleven- to 14-year follow-up results of cementless total hip arthroplasty using a third-generation alumina ceramic-on-ceramic bearing. J Arthroplasty. 2012; 27(5):736–741. doi:10.1016/j.arth.2011.08.017 [CrossRef]
  43. Girard J, Bocquet D, Autissier G, Fouilleron N, Fron D, Migaud H. Metal-on-metal hip arthroplasty in patients thirty years of age or younger. J Bone Joint Surg Am. 2010; 92(14):2419–2426. doi:10.2106/JBJS.I.01644 [CrossRef]
  44. D'Antonio JA, Capello WN, Naughton M. Ceramic bearings for total hip arthroplasty have high survivorship at 10 years. Clin Orthop Relat Res. 2012; 470(2):373–381. doi:10.1007/s11999-011-2076-7 [CrossRef]
  45. Amstutz HC, Le Duff MJ, Campbell PA, Gruen TA, Wisk LE. Clinical and radiographic results of metal-on-metal hip resurfacing with a minimum ten-year follow-up. J Bone Joint Surg Am. 2010; 92(16):2663–2671. doi:10.2106/JBJS.I.01715 [CrossRef]
  46. Coulter G, Young DA, Dalziel RE, Shimmin AJ. Birmingham hip resurfacing at a mean of ten years: results from an independent centre. J Bone Joint Surg Br. 2012; 94(3):315–321. doi:10.1302/0301-620X.94B3.28185 [CrossRef]
  47. Yoon HJ, Yoo JJ, Yoon KS, Koo KH, Kim HJ. Alumina-on-alumina THA performed in patients younger than 30 years: a 10-year minimum follow-up study. Clin Orthop Relat Res. 2012; 470(12):3530–3536. doi:10.1007/s11999-012-2493-2 [CrossRef]
  48. Streit MR, Schroder K, Korber M, et al. High survival in young patients using a second generation uncemented total hip replacement. Int Orthop. 2012; 36(6):1129–1136. doi:10.1007/s00264-011-1399-z [CrossRef]
  49. Hwang KT, Kim YH, Kim YS, Choi IY. Cementless total hip arthroplasty with a metal-on-metal bearing in patients younger than 50 years. J Arthroplasty. 2011; 26(8):1481–1487. doi:10.1016/j.arth.2011.02.020 [CrossRef]
  50. Babovic N, Trousdale RT. Total hip arthroplasty using highly cross-linked polyethylene in patients younger than 50 years with minimum 10-year follow-up. J Arthroplasty. 2013; 28(5):815–817. doi:10.1016/j.arth.2012.12.005 [CrossRef]

Clinical Results at Final Follow-up

Clinical QuestionnaireMean±SD (Range)
Western Ontario and McMaster Universities Osteoarthritis Indexa94±9.7 (49–100)
Patient-administered questionnaire scoreb65±11 (0–100)
Hospital for Special Surgery hip scorea37±4 (0–40)

Participation in Recreational Activities at Time of Final Follow-up

Activity Performed 1–3 Times per WeekPatients
Walking >1 mile57%
Gym exercise32.6%
Gardening24.5%
Golf14.3%
Tennis7.1%

Published Long-term Results and Survivorship of Total Hip Arthroplasty and Hip Resurfacing in Patients Younger Than 65 Years

StudyMean Age (Range), yMean Follow-up (Range), yNo. of HipsBearingsSurvivorshipRevisions
McMinn et al,29 201148.3 (27–55)10.3 (8–15)403Hip resurfacing98%1.2% femoral neck fracture or collapse 0.3% (10 hips) adverse local tissue reaction
Kim et al,14 201345.3 (21–49)12.4 (11–13)100Ceramic on ceramic99% overall5% squeaking or clicking
100% wear1% dislocation
100Ceramic on highly cross-linked polyethylene99% overall0% aseptic osteolysis
100% wear1% dislocation
Yoon et al,47 201224 (18–30)11.5 (10–13.5)75Ceramic on ceramic99%3% squeaking
1.3% fracture
Lee et al,32 201041 (18–65)11 (10–12)86Ceramic on ceramic99%1% squeaking
2% fracture
Kim et al,16 201045.5 (20–50)8.5 (7–9)73Ceramic on highly cross-linked polyethylene100%1.2% dislocation
Kim et al,15 201328 (21–29)10.8 (10–12)60Ceramic on highly cross-linked polyethylene100%1 dislocation
Girard et al,43 201025 (15–30)9 (5–12.8)47Metal on metal94.5%2% (1 hip) aseptic loosening
Streit et al,48 201249 (25–60)12 (10–15)89Metal on metal94%1% (1 hip) aseptic loosening
Hwang et al,49 201139.8 (19–50)12.4 (11)78Metal on metal98.7%2.5% (2 hips) aseptic loosening
Babovic and Trousdale,50 201339 (15–50)10.4 (10–12)54Metal on highly cross-linked polyethylene100%-
Current study51 (24–60)12.3 (11–13)103Metal on highly cross-linked polyethylene100%1 dislocation

Registry Results With Different Bearings in Uncemented Total Hip Arthroscopy and Hip Resurfacing

RegistryAustralian, 20132England and Wales, 20135
Follow-up, mean, y129
Highly cross-linked polyethylene
  Metal on highly cross-linked polyethylene5.4%4.3%
  Ceramic on highly cross-linked polyethylene5.6%3.0%
Ceramic on ceramic6.2%4.1%
Metal on metal18.6%17.6%
Hip resurfacing11.2%12.3%
Authors

The authors are from the Hospital for Special Surgery (CSR, ASR, DN), New York, New York; the Arthritis & Joint Replacement Clinic (AAR), Maharashtra, India; and the Bronx-Lebanon Hospital Center and the Hospital for Joint Disease/NYU Langone Medical Center (MM), New York, New York.

Drs Ramteke, Nawabi, and Meftah have no relevant financial relationships to disclose. Dr C S Ranawat receives research support and royalties from DePuy and Stryker. Dr A S Ranawat holds stock in Conformis and Mako and receives research support from DePuy and Stryker.

Correspondence should be addressed to: Morteza Meftah, MD, Hospital for Joint Disease/NYU Langone Medical Center, 301 E 17th St, 11th Fl, New York, NY 10003 ( MeftahM@hss.edu).

Received: June 01, 2015
Accepted: July 13, 2015

10.3928/01477447-20160119-02

Advertisement

Sign up to receive

Journal E-contents
Advertisement