Journal of Refractive Surgery

Original Article 

Resolving Refractive Error After Cataract Surgery: IOL Exchange, Piggyback Lens, or LASIK

Roberto Fernández-Buenaga, MD; Jorge L. Alió, MD, PhD; Andrés L. Pérez Ardoy, MsC; Adrián Larrosa Quesada, MsC; Laura Pinilla-Cortés, MD; Rafael I. Barraquer, PhD

Abstract

PURPOSE:

To evaluate the efficacy, predictability, and safety of three different procedures (intraocular lens [IOL] exchange, piggyback lens implantation, and LASIK) to correct residual refractive error following cataract surgery.

METHODS:

A retrospective multicenter study comprised 65 eyes of 54 patients that underwent phacoemulsification, resulting in a unacceptable final refractive error. Eyes were divided into three groups: eyes that had an IOL lens exchange (17 eyes), eyes that had a piggyback lens implanted (20 eyes), and eyes that had LASIK (28 eyes).

RESULTS:

No differences between the IOL exchange and piggyback lens groups in the spherical equivalent, sphere, or cylinder were found (P = .072, .436, and .081, respectively). The LASIK group showed a statistically significant reduction in spherical equivalent and refractive cylinder when compared with the IOL exchange group (P < .001 and P = .001, respectively). The LASIK group showed statistically significant reduced refractive cylinder in comparison with the piggyback lens group (P = .002). The median efficacy index was 0.58 (range: 0.28 to 0.93), 0.75 (range: 0.65 to 0.92), and 0.91 (range: 0.85 to 1.14) in the IOL exchange, piggyback lens, and LASIK groups, respectively. Statistically significant differences were found between the IOL exchange and LASIK groups (P = .004) and the piggyback lens and LASIK groups (P = .003). No statistically significant differences were detected in the safety index among groups (P = .094). The predictability (±1 diopters of final spherical equivalent) was 62.5% of eyes in the IOL exchange group, 85% of eyes in the piggyback lens group, and 100% of eyes in the LASIK group.

CONCLUSIONS:

The three procedures were effective. The LASIK group showed the best outcomes in efficacy and predictability.

[J Refract Surg. 2013;29(10):676–683.]

From Vissum Corporation, Alicante, Spain (RF-B, JLA, ALPA, ALQ); Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain (JLA); and Institut Universitari Barraquer, Universitat Autónoma de Barcelona, Spain (LPC, RIB).

Supported in part by a grant from the Spanish Ministry of Health, Instituto Carlos III. The two centers that participated in this study (Vissum Corporation and Institut Universitari Barraquer) belong to Red Temática de Investigación Oftalmológica, “Patología ocular del envejecimiento, calidad visual y calidad de vida,” and Subproyecto de Calidad Visual (RD07/0062), which is a cooperative network for ophthalmic research sponsored by the Spanish Ministry of Health.

The authors have no financial or proprietary interest in the materials presented herein.

AUTHOR CONTRIBUTIONS

Study concept and design (RF-B, JLA); data collection (RF-B, ALPA, ALQ, LPC); analysis and interpretation of data (RF-B, RIB); drafting of the manuscript (RF-B, ALPA, ALQ); critical revision of the manuscript (JLA, LPC, RIB); supervision (JLA, RIB)

Correspondence: Jorge L. Alió, MD, PhD, Avda de Denia s/n, Edificio Vissum, 03016 Alicante, Spain. E-mail: jlalio@vissum.com

Received: February 20, 2013
Accepted: June 12, 2013
Posted Online: September 02, 2013

Abstract

PURPOSE:

To evaluate the efficacy, predictability, and safety of three different procedures (intraocular lens [IOL] exchange, piggyback lens implantation, and LASIK) to correct residual refractive error following cataract surgery.

METHODS:

A retrospective multicenter study comprised 65 eyes of 54 patients that underwent phacoemulsification, resulting in a unacceptable final refractive error. Eyes were divided into three groups: eyes that had an IOL lens exchange (17 eyes), eyes that had a piggyback lens implanted (20 eyes), and eyes that had LASIK (28 eyes).

RESULTS:

No differences between the IOL exchange and piggyback lens groups in the spherical equivalent, sphere, or cylinder were found (P = .072, .436, and .081, respectively). The LASIK group showed a statistically significant reduction in spherical equivalent and refractive cylinder when compared with the IOL exchange group (P < .001 and P = .001, respectively). The LASIK group showed statistically significant reduced refractive cylinder in comparison with the piggyback lens group (P = .002). The median efficacy index was 0.58 (range: 0.28 to 0.93), 0.75 (range: 0.65 to 0.92), and 0.91 (range: 0.85 to 1.14) in the IOL exchange, piggyback lens, and LASIK groups, respectively. Statistically significant differences were found between the IOL exchange and LASIK groups (P = .004) and the piggyback lens and LASIK groups (P = .003). No statistically significant differences were detected in the safety index among groups (P = .094). The predictability (±1 diopters of final spherical equivalent) was 62.5% of eyes in the IOL exchange group, 85% of eyes in the piggyback lens group, and 100% of eyes in the LASIK group.

CONCLUSIONS:

The three procedures were effective. The LASIK group showed the best outcomes in efficacy and predictability.

[J Refract Surg. 2013;29(10):676–683.]

From Vissum Corporation, Alicante, Spain (RF-B, JLA, ALPA, ALQ); Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain (JLA); and Institut Universitari Barraquer, Universitat Autónoma de Barcelona, Spain (LPC, RIB).

Supported in part by a grant from the Spanish Ministry of Health, Instituto Carlos III. The two centers that participated in this study (Vissum Corporation and Institut Universitari Barraquer) belong to Red Temática de Investigación Oftalmológica, “Patología ocular del envejecimiento, calidad visual y calidad de vida,” and Subproyecto de Calidad Visual (RD07/0062), which is a cooperative network for ophthalmic research sponsored by the Spanish Ministry of Health.

The authors have no financial or proprietary interest in the materials presented herein.

AUTHOR CONTRIBUTIONS

Study concept and design (RF-B, JLA); data collection (RF-B, ALPA, ALQ, LPC); analysis and interpretation of data (RF-B, RIB); drafting of the manuscript (RF-B, ALPA, ALQ); critical revision of the manuscript (JLA, LPC, RIB); supervision (JLA, RIB)

Correspondence: Jorge L. Alió, MD, PhD, Avda de Denia s/n, Edificio Vissum, 03016 Alicante, Spain. E-mail: jlalio@vissum.com

Received: February 20, 2013
Accepted: June 12, 2013
Posted Online: September 02, 2013

Phacoemulsification with intraocular lens (IOL) implantation is one of the most common surgeries performed. Despite new advances in cataract surgery, unsatisfactory visual outcomes as a result of a residual refractive error occasionally occur. This may be due to different causes, such as inaccuracies in the biometric analysis,1–3 inadequate selection of the IOL power, limitations of the calculations formulas (especially in extreme ametropia), or IOL positional errors.4

Previous studies have shown good efficacy, predictability, and safety for myopic and hyperopic LASIK and photorefractive keratectomy enhancements after cataract surgery.5–11 Lens-based procedures are also useful alternatives to consider.12,13 It should be noted that some surgeons do not have excimer laser in their centers; thus lens procedures become the only possible option in these cases.

In a recent report analyzing refractive data from more than 17,000eyesaftercataractsurgery,emmetropiawasonlyreached in 55% of eyes planned for that goal.14 These outcomes highlight that refractive error after cataract surgery is an important issue; hence investigation about the performance of the different approaches to resolve it is mandatory. Surprisingly, there is limited literature comparing LASIK with lens-based procedures such as IOL exchange or piggyback lenses for correction of residual ametropia after cataract surgery.15 Therefore, the aim of this study was to present and compare the results assessing the efficacy, predictability, and safety of three different procedures to correct residual refractive error after cataract surgery: LASIK, IOL exchange, and piggyback lens implantation.

Patients and Methods

Patients

This observational multicenter, retrospective consecutive study comprised 65 eyes of 54 patients that underwent phacoemulsification resulting in an unacceptable final refractive error. Charts of patients from centers of the research group Red Temática de Investigación Oftalmológica (a cooperative network for ophthalmic research subsidized by the Spanish Ministry of Health) with at least 6 months of follow-up and stable refraction were reviewed. The postoperative cataract enhancement procedures were considered in patients with refractive error after uneventful microincision cataract surgery with monofocal IOL implantation who refused to wear corrective lenses and with a normal anterior segment and no capsular opacities or general health problems. The technique in each case was selected by the surgeon depending on the surgeon’s criteria and on the excimer laser availability.

Exclusion criteria included ocular surgery (other than phacoemulsification) or the presence of corneal or other ocular pathology. Informed consent was obtained from all patients before the refractive enhancement procedure. Institutional review board approval was obtained from the local ethics committee.

The eyes were divided into three groups to compare three different surgical techniques. The IOL exchange group comprised eyes that had an IOL exchange with implantation of a new calculated IOL (17 eyes), the piggyback lens group included those cases that had a piggyback lens implanted (20 eyes), and the LASIK group consisted of those eyes that had a LASIK procedure after phacoemulsification (28 eyes).

Surgical Technique

The original cataract surgery was performed using phacoemulsification with posterior chamber IOL implantation. The technique included curvilinear continuous capsulotomy and in-the-bag IOL placement.

There was not a standard protocol for the IOL exchange technique. The surgical technique depended on the surgeon’s preference in every case. All IOLs used for exchange were placed in the bag and the same IOL model was used for original implantation and IOL exchange. No toric IOL models were used for the IOL exchange. The IOL power calculation was repeated using the IOLMaster optical biometer (Carl Zeiss Meditec, Inc., Dublin, CA) with the setting “pseudophakic.”

Piggyback lens calculation was performed following the Holladay IOL calculation software (Holladay Consulting, Inc., Bellaire, TX). The IOL implanted in sulcus was the AcrySof MA60 (Alcon Laboratories, Inc., Fort Worth, TX) in all cases.

The LASIK procedures were performed under topical anesthesia with oxybuprocaine 0.4%. Excimer laser ablation was performed in all cases on the stromal bed by means of the Schwind Esiris excimer laser (SCHWIND eye-tech-solutions, Kleinostheim, Germany), using an energy fluency of 180 mJ/cm2, a repetition rate ranging from 5 to 50 Hz, and a 0.8-mm flying spot. The optical zone diameter ranged from 6.0 to 6.5 mm and was selected according to the scotopic pupil size and corneal thickness. Temperature and humidity conditions were maintained within the ranges stated by the manufacturer. All procedures were centered at the pupillary center.

Flap creation was performed using the IntraLase 30-kHz femtosecond laser (Abbott Medical Optics, Inc., Santa Ana, CA). Superior hinged flaps with 100-μm thickness were created in all cases.

Outcome Measures

The main outcome measures of the study were postoperative uncorrected distance visual acuity, postoperative corrected distance visual acuity (CDVA), and the spherical equivalent (SE), sphere, and refractive cylinder. Other measures studied were the efficacy index (postoperative uncorrected distance visual acuity/pre-operative CDVA), safety index (postoperative CDVA/preoperative CDVA), and the predictability. The predictability was evaluated by calculating the percentage of eyes with a postoperative SE within ±0.50 to ±1.00 diopters (D) of the intended correction.

Statistical analysis was performed using SPSS for Windows (version 15.0; SPSS, Inc., Chicago, IL). Non-parametric tests were used to compare the outcomes among groups. Because the number in each group was less than 30, data were expressed as medians. A P value less than .05 was considered significant.

Results

The study evaluated 65 eyes of patients with ages ranging from 28 to 82 years old. The IOL exchange group comprised 17 eyes, the piggyback lens group 20 eyes, and the LASIK group 28 eyes. Table 1 shows the preoperative and demographic patient data. There were no statistically significant differences among the three groups in preoperative age, SE, sphere, and refractive cylinder (P ⩾ .05; Kruskal–Wallis test) (Table 1). Therefore, the three groups were matched for these variables.

Preoperative and Demographic Patient Dataa

Table 1:

Preoperative and Demographic Patient Data

Table 2 summarizes the visual and refractive outcomes before and 6 months after the correcting procedure in each group.

Visual and Refractive Outcomes Before and 6 Months After the Correcting Procedure in Each Groupa

Table 2:

Visual and Refractive Outcomes Before and 6 Months After the Correcting Procedure in Each Group

IOL Exchange

The IOL models implanted in the original cataract surgery were the following: Acrysof SA60AT (Alcon Laboratories, Inc.) (6 eyes), Acrysof MA60BM (Alcon Laboratories, Inc.) (2 eyes), Acri.Tec Acrismart 48S (Carl Zeiss Meditec, Inc.) (2 eyes), Acrysof MA30BA (Alcon Laboratories, Inc.) (1 eye), Acrysof SN60WF (Alcon Laboratories, Inc.) (1 eye), Akreos Adapt (Bausch & Lomb, Rochester, NY) (1 eye), AMO Z9002 (Abbott Medical Optics, Inc.) (1 eye), Corneal ACR6D (Groupe Corneal Laboratoires, Paris, France) (1 eye), and unknown model (2 eyes).

The percentage of eyes within ±0.50 D of final SE was 31.3%. When we considered the predictability within ±1.00 D of final SE, 62.5% of the eyes were within these limits. A total of 5 eyes (29.4%) lost one or more lines of CDVA after the IOL exchange surgery.

Six eyes underwent surgery for a myopic correction and 11 eyes for hyperopic correction. Table 3 summarizes the results obtained in both subgroups of eyes (myopia vs hyperopia).

Results in Myopia and Hyperopia for the 3 Groupsa

Table 3:

Results in Myopia and Hyperopia for the 3 Groups

In the myopia subgroup, 16.6% of eyes achieved a final SE of ±0.50 D compared with 27.7% in the hyperopia subgroup (P = .513). When the cut point was considered at ±1.00 D, 33.3% of the myopic eyes were within this limit compared to 63.63% in the hyperopia subgroup (P = .210).

Piggyback Lens

In the predictability analysis, 65% of eyes achieved a final SE within ±0.50 D and 85% within ±1.00 D. Seven eyes (35%) lost one or more lines of vision after the piggyback procedure.

Four eyes underwent surgery for myopic correction and 16 eyes for hyperopic correction. Table 3 summarizes the results observed in both subgroups. Regarding the predictability analysis, 75% of the myopic eyes and 68.75% of the hyperopic eyes were within ±0.50 D of final SE (P = .482). When the cut point was set at ±1.00 D, 100% of myopic eyes and 81.25% of hyperopic eyes achieved this result (P = .348).

LASIK

In this group, 92.85% of eyes showed a final SE within ±0.50 D and 100% of eyes within ±1.00 D. A total of 2 eyes (7.14%) lost one or more lines of CDVA after the correcting procedure.

A total of 15 eyes underwent surgery for myopic correction and 13 eyes for hyperopic correction. Table 3 shows the outcomes in both subgroups.

In the predictability comparison, 93.3% of myopic eyes and 92.3% of hyperopic eyes showed a final SE within ±0.50 D (P = .916), whereas 100% of myopic and hyperopic eyes were within ±1.00 D.

Comparative Analysis Among Groups

IOL exchange was the procedure that corrected the highest amount of diopters. In myopia, it achieved a median sphere reduction of 5.75 D and a median SE reduction of 6.12 D. Piggyback lens implantation and LASIK corrected 1.57 and 0.74 D of sphere and 1.50 and 1.00 D of SE, respectively.

In hyperopia, the IOL exchange also achieved the largest correction in sphere and SE, 3.25 and 3.8 D, respectively. Piggyback lens implantation and LASIK corrected 2.37 and 1.88 of sphere and 2.43 and 1.50 D of SE, respectively.

There were statistically significant differences among the three groups in the SE (P = .002) (Figure 1) and the refractive cylinder (P = .001) (Figure 2). However, no statistically significant differences were found in the sphere (P = .480).

Comparison of the final spherical equivalent (SE) among the three groups. Group 3 (LASIK) achieved the best outcome with the smallest results dispersion.

Figure 1.

Comparison of the final spherical equivalent (SE) among the three groups. Group 3 (LASIK) achieved the best outcome with the smallest results dispersion.

Comparison of the final refractive cylinder among the three groups. Group 3 (LASIK) achieved the best outcome with the smallest results dispersion.

Figure 2.

Comparison of the final refractive cylinder among the three groups. Group 3 (LASIK) achieved the best outcome with the smallest results dispersion.

When the IOL exchange and piggyback lens groups were compared, no differences in the SE, sphere, or cylinder (P = .072, .436, and .081, respectively) were found.

When comparing the IOL exchange and LASIK groups, we found statistically significant differences regarding the SE and the refractive cylinder (P < .001 and P = .001, respectively). However, there was no statistically significant difference in the sphere (P = .225).

Outcomes between the piggyback lens and LASIK groups were also compared. In this analysis, only statistically significant differences in the refractive cylinder could be found (P = .002). No differences were found in the SE and in the sphere (P = .056 and P = .751, respectively).

Figure 3 shows an among groups comparison of the efficacy index. We found statistically significant differences among the three groups (P = .002).

The efficacy index mean and distribution among groups. The highest value was achieved by group 3 (LASIK).

Figure 3.

The efficacy index mean and distribution among groups. The highest value was achieved by group 3 (LASIK).

A comparison of the efficacy between the IOL exchange and piggyback lens groups was performed and no differences between groups were detected (P = .271). We also compared the efficacy between the IOL exchange and LASIK groups. The median efficacy of the IOL exchange group was 0.58 (range: 0.28 to 0.93), whereas in the LASIK group it was 0.91 (range: 0.85 to 1.14). These differences were statistically significant (P = .004).

The median efficacy value in the piggyback lens group was 0.75 (range: 0.65 to 0.92). When comparing the piggyback lens and LASIK groups, a statistically significant difference was also found (P = .003).

The safety index was analyzed among groups, but no statistically significant differences could be found (P = .094). However, the proportion of eyes that lost one or more lines of CDVA was 29.4%, 35%, and 7.14% in the IOL exchange, piggyback lens, and LASIK groups, respectively. In the comparative analysis, these findings were significantly different (P = .048). No eye in the LASIK group lost more than two lines of CDVA, but 1 eye and 3 eyes did in the IOL exchange and piggyback lens groups, respectively.

When we compared the predictability, the percentage of eyes within ±0.50 D of final SE was 31.3% in the IOL exchange group, 65% in the piggyback lens group, and 92.9% in the LASIK group. The statistical analysis showed these differences to be significant (P = .000).

When we considered the predictability within ±1.00 D of final SE, the outcomes were the following: 62.5% of the eyes in the IOL exchange group, 85% of the eyes in the piggyback lens group, and 100% of the eyes in the LASIK group. These differences were also statistically significant. (P = .003) (Figure 4).

The predictability achieved in each group. (A) Intraocular exchange group, (B) piggyback lens group, and (C) LASIK group.

Figure 4.

The predictability achieved in each group. (A) Intraocular exchange group, (B) piggyback lens group, and (C) LASIK group.

Discussion

Cataract surgery is the most common intraocular surgery performed. Due to the technical progress, the incidence of severe complications has been minimized. Currently, the most common postoperative problems have been reduced to refractive inaccuracies.2–4,16 Postoperative induced astigmatism is usually the most undesired surprise after cataract surgery, although the use of microincisional surgery has significantly improved the control of postoperative astigmatism.17,18 Refinement of the refractive outcomes after cataract surgery with excimer laser has been widely described as an effective and safe method.5–11,19–25 Other alternatives to correct postoperative cataract surgery refractive errors are the lens-based methods IOL exchange and piggyback lens implantation. In a recent study of causes for pseudophakic IOL exchange, the refractive error was the second most important cause.26 The same results have been shown by both the American Society of Cataract and Refractive Surgery and European Society of Cataract and Refractive Surgeons surveys.27,28 Hence, the refractive error after cataract surgery is a relatively common issue in everyday clinical practice.

In this study, it was shown that the three methods of correction are capable of improving refraction in myopic and hyperopic eyes (Table 3), but not myopic eyes treated by piggyback lens implantation. In this subgroup, although the SE and the sphere were reduced after the surgery, these differences were not significant, probably due to the small sample size.

However, the aim of this study was to compare the three different approaches to determine which approach was the most accurate and safest to correct refractive errors after cataract surgery. In the comparative analysis among groups, statistically significant differences were found in the SE and in the refractive cylinder. When compared with the IOL exchange group, the LASIK group had statistically significant better outcomes for the SE and the refractive cylinder. Significant differences were also detected between the LASIK and piggyback lens groups with the cylinder favoring the former (Figure 2). Therefore, there were no differences in the final sphere among groups. Nevertheless, the cylinder outcome is what makes the LASIK procedure more accurate than the IOL exchange or piggyback lens technique. Refractive cylinder was decreased after surgery in the LASIK group, stable in the piggyback lens group, and increased in the IOL exchange group. We believe the reason for this astigmatic worsening found in the IOL exchange group was that wound enlargement was sometimes required to remove the IOL. The implantation of a toric IOL could be an interesting option to improve the astigmatic outcome when an IOL exchange is planned. We considered that the only limitation for this strategy would be to accurately estimate the amount of induced astigmatism with the wound enlargement.

When analyzing Table 1 and Figures 12, we can see a smaller dispersion in the final SE and cylinder of the LASIK group and a wider range in both the piggyback lens and IOL exchange groups. However, it is important to consider that the preoperative range of values was already wider in the IOL exchange and piggyback lens groups and consequently less predictable to handle when compared to preoperative values of the LASIK group.

The efficacy index showed better outcomes in the LASIK group than in the IOL exchange and piggyback lens groups (Figure 3). However, no statistically significant differences were found between IOL exchange and piggyback lens implantation in this index. In the predictability analysis, there were also differences among groups with the best outcome in the LASIK group followed by the piggyback lens group. The worst predictability was found in the IOL exchange group (Figure 4). It is remarkable that the percentage of eyes within ±0.50 D of final SE in the LASIK group was 92.9%. This result is slightly better than the predictability reported in previous studies.10,11,21

We believe it is necessary to remember that although IOL exchange shows the least accurate results, it was used in those eyes with the largest preoperative residual defects. In fact, in the myopic eyes, the SE reduction achieved in the IOL exchange group was 6.12 D compared to 1.50 and 1.00 D in the piggyback lens and LASIK groups, respectively. In the hyperopic eyes, IOL exchange reduced the SE by 3.80 D, whereas in the piggyback lens and LASIK groups the reduction was 1.88 and 1.50 D, respectively.

Regarding the safety index, no statistically significant differences were found among groups. Nevertheless, the proportion of eyes that lost one or more lines of CDVA was significantly different among groups. This percentage was four to five times higher in the IOL exchange and piggyback lens groups in comparison with the LASIK group (7.14%). Indeed, no eye of those treated with LASIK lost more than two lines of visual acuity, whereas 1 eye in the IOL exchange group and 3 eyes in the piggyback lens group did. Our outcomes in this parameter are worse than those reported in previous studies; we found that close to one-third of patients who underwent surgery with a lens-based method lost one or more lines of visual acuity, whereas another study reported only 11% of eyes.15

To the best of our knowledge, there is only one study comparing these methods used to correct residual refractive defects.15 However, in that study the authors established a comparison between LASIK and lens-based correcting methods; including piggyback lens implantation and IOL exchange in the same group. We believe piggyback lens implantation and IOL exchange should not be analyzed together because both surgical procedures are different. In fact, although piggyback lenses may be implanted through a small incision, it is sometimes necessary to enlarge the incision to perform an IOL exchange, resulting in incomparable astigmatic outcomes. However, the authors found comparable results between the LASIK group and the lens-based group in the final SE and safety. On the contrary, our results showed that LASIK is superior to IOL exchange and piggyback lens implantation in final SE, efficacy, predictability, and safety.

Refractive error after cataract surgery is a relevant issue. Although it has been previously mentioned, the intended emmetropia is finally achieved in less than two-thirds of patients.14 This explains why it is necessary to know the performance of the methods used to resolve these unsatisfactory situations. The results of this study show that LASIK was the most accurate procedure to correct residual ametropia after cataract surgery. Lens-based procedures (IOL exchange or piggyback lens implantation) are also effective methods and should be the method of choice in those cases with extreme ametropia, corneal abnormalities, or when there is not an available excimer laser platform. A randomized controlled prospective study comparing the three procedures is necessary to confirm these findings.

References

  1. Snead MP, Rubinstein MP, Lea SH, Haworth SM. Calculated versus A-scan result for axial length using different types of ultrasound probe tip. Eye (Lond). 1990;4:718–722. doi:10.1038/eye.1990.101 [CrossRef]
  2. Pierro L, Modorati G, Brancato R. Clinical variability in keratometry, ultrasound biometry measurements, and emmetropic intraocular lens power calculation. J Cataract Refract Surg. 1991;17:91–94. doi:10.1016/S0886-3350(13)80991-1 [CrossRef]
  3. Raman S, Redmond R. Reasons for secondary surgical intervention after phacoemulsification with posterior chamber lens implantation. J Cataract Refract Surg. 2003;29:513–517. doi:10.1016/S0886-3350(02)01637-1 [CrossRef]
  4. Erickson P. Effects of intraocular lens position errors on postoperative refractive error. J Cataract Refract Surg. 1990;16:305–311. doi:10.1016/S0886-3350(13)80699-2 [CrossRef]
  5. Alfonso JF, Fernández-Vega L, Montés-Micó R, Valcárcel B. Femtosecond laser for residual refractive error correction after refractive lens exchange with multifocal intraocular lens implantation. Am J Ophthalmol. 2008;146:244–250. doi:10.1016/j.ajo.2008.03.022 [CrossRef]
  6. Leccisotti A. Secondary procedures after presbyopic lens exchange. J Cataract Refract Surg. 2004;30:1461–1465. doi:10.1016/j.jcrs.2003.11.056 [CrossRef]
  7. Pop M, Payette Y, Amyot M. Clear lens extraction with intraocular lens followed by photorefractive keratectomy or laser in situ keratomileusis. Ophthalmology. 2001;108:104–111. doi:10.1016/S0161-6420(00)00451-6 [CrossRef]
  8. Ayala MJ, Pérez-Santonja JJ, Artola A, Claramonte P, Alió JL. Laser in situ keratomileusis to correct residual myopia after cataract surgery. J Refract Surg. 2001;17:12–16.
  9. Norouzi H, Rahmati-Kamel M. Laser in situ keratomileusis for correction of induced astigmatism from cataract surgery. J Refract Surg. 2003;19:416–424.
  10. Muftuoglu O, Prasher P, Chu C, et al. Laser in situ keratomileusis for residual refractive errors after apodized diffractive multifocal intraocular lens implantation. J Cataract Refract Surg. 2009;35:1063–1071. doi:10.1016/j.jcrs.2009.01.028 [CrossRef]
  11. Piñero DP, Ayala Espinosa MJ, Alió JL. LASIK outcomes following multifocal and monofocal intraocular lens implantation. J Refract Surg. 2010;26:569–577. doi:10.3928/1081597X-20091030-02 [CrossRef]
  12. Habot-Wilner Z, Sachs D, Cahane M, et al. Refractive results with secondary piggyback implantation to correct pseudophakic refractive errors. J Cataract Refract Surg. 2005;31:2101–2103. doi:10.1016/j.jcrs.2005.05.023 [CrossRef]
  13. Jin GJ, Crandall AS, Jones JJ. Intraocular lens exchange due to incorrect lens power. Ophthalmology. 2007;114:417–424. doi:10.1016/j.ophtha.2006.07.041 [CrossRef]
  14. Behndig A, Montan P, Stenevi U, Kugelberg M, Zetterström C, Lundström M. Aiming for emmetropia after cataract surgery: Swedish National Cataract Register study. J Cataract Refract Surg. 2012;38:1181–1186. doi:10.1016/j.jcrs.2012.02.035 [CrossRef]
  15. Jin GJ, Merkley KH, Crandall AS, Jones YJ. Laser in situ keratomileusis versus lens-based surgery for correcting residual refractive error after cataract surgery. J Cataract Refract Surg. 2008;34:562–569. doi:10.1016/j.jcrs.2007.11.040 [CrossRef]
  16. Høvding G, Natvik C, Sletteberg O. The refractive error after implantation of a posterior chamber intraocular lens: the accuracy of IOL power calculation in a hospital practice. Acta Ophthalmol (Copenh). 1994;72:612–616. doi:10.1111/j.1755-3768.1994.tb07188.x [CrossRef]
  17. Alió J, Rodríguez-Prats JL, Galal A, Ramzy M. Outcomes of microincision cataract surgery versus coaxial phacoemulsification. Ophthalmology. 2005;112:1997–2003. doi:10.1016/j.ophtha.2005.06.024 [CrossRef]
  18. Alió J, Rodriguez-Prats JL, Galal A. Advances in microincision cataract surgery intraocular lenses. Curr Opin Ophthalmol. 2006;17:80–93.
  19. Jendritza BB, Knorz MC, Morton S. Wavefront-guided excimer laser vision correction after multifocal IOL implantation. J Refract Surg. 2008;24:274–279.
  20. Kuo IC, O’Brien TP, Broman AT, Ghajarnia M, Jabbur NS. Excimer laser surgery for correction of ametropia after cataract surgery. J Cataract Refract Surg. 2005;31:2104–2110. doi:10.1016/j.jcrs.2005.08.023 [CrossRef]
  21. Kim P, Briganti EM, Sutton GL, Lawless MA, Rogers CM, Hodge C. Laser in situ keratomileusis for refractive error after cataract surgery. J Cataract Refract Surg. 2005;31:979–986. doi:10.1016/j.jcrs.2004.08.054 [CrossRef]
  22. Güell JL, Gris O, de Muller A, Corcostegui B. LASIK for the correction of residual refractive errors from previous surgical procedures. Ophthalmic Surg Lasers. 1999;30:341–349.
  23. Artola A, Ayala MJ, Claramonte P, Pérez-Santonja JJ, Alió JL. Photorefractive keratectomy for residual myopia after cataract surgery. J Cataract Refract Surg. 1999;25:1456–1460. doi:10.1016/S0886-3350(99)00233-3 [CrossRef]
  24. Maloney RK, Chan WK, Steinert R, Hersh P, O’Connell M. A multicenter trial of photorefractive keratectomy for residual myopia after previous ocular surgery. Summit Therapeutic Refractive Study Group. Ophthalmology. 1995;102:1042–1052. doi:10.1016/S0161-6420(95)30913-X [CrossRef]
  25. Macsai MS, Fontes BM. Refractive enhancement following presbyopia-correcting intraocular lens implantation. Curr Opin Ophthalmol. 2008;19:18–21. doi:10.1097/ICU.0b013e3282f14d9f [CrossRef]
  26. Fernández-Buenaga R, Alio JL, Muñoz-Negrete FJ, Barraquer Compte RI, Alio-Del Barrio JL. Causes of IOL explantation in Spain. Eur J Ophthalmol. 2012;22:762–768.
  27. Mamalis N, Davis B, Nilson CD, Hickman MS, Leboyer RM. Complications of foldable intraocular lenses requiring explantation or secondary intervention: 2003 survey update. J Cataract Refract Surg. 2004;30:2209–2218. doi:10.1016/j.jcrs.2004.06.051 [CrossRef]
  28. Mamalis N, Brubaker J, Davis D, Espandar L, Werner L. Complications of foldable intraocular lenses requiring explantation or secondary intervention: 2007 survey update. J Cataract Refract Surg. 2008;34:1584–1591. doi:10.1016/j.jcrs.2008.05.046 [CrossRef]

Preoperative and Demographic Patient Dataa

ParameterAll Patients Mean ± SD (Range)IOL Exchange Median (Range)Piggyback Lens Median (Range)LASIK Median (Range)
Age (y)53.3 ± 11.9 (28 to 82)53 (43 to 68)b56 (49 to 65)b47 (43 to 57)b
Sex
  Male (%)54.764.763.242.9
  Female (%)45.335.336.857.1
SE0.4 ± 3.6 (−10.5 to +15)1.8 (−6.8 to +3.6)c1.6 (0.03 to +2.4)c−0.3 (−1 to +1.4)c
Sphere0.8 ± 3.7 (−10.2 to +14.5)1 (−5.2 to +3.8)d2 (0.5 to +3)d0.2 (−0.7 to +1.8)d
Refractive cylinder−1.2 ± 1 (−4 to +1.7)−0.75 (−2.5 to −0.5)e−1 (−1.6 to −0.5)e−1.2 (−1.6 to −0.6)e

Visual and Refractive Outcomes Before and 6 Months After the Correcting Procedure in Each Groupa

ParameterIOL ExchangePiggyback LensLASIK



Preoperative (Range)6 Months (Range)Preoperative (Range)6 Months (Range)Preoperative (Range)6 Months (Range)
CDVA0.22 (0.14 to 0.39)0.22 (0.08 to 0.39)0.07 (0.01 to 0.19)0.07 (0.00 to 0.28)0.15 (0.04 to 0.21)0.09 (0.02 to 0.15)
SE1.87 (−6.81 to 3.62)−0.87 (−2.37 to −0.06)1.62 (0.03 to 2.43)−0.31 (−0.84 to 0.43)−0.37 (−1 to 1.47)0.00 (−0.09 to 0.46)
Sphere1 (−5.25 to 3.87)−0.25 (−1.5 to 1.5)2 (0.50 to 3)0.50 (0.00 to 0.75)0.25 (−0.75 to 1.87)0.12 (0.00 to 0.75)
Cylinder−0.75 (−2.5 to −0.5)−2 (−2.87 to −0.81)−1 (−1.62 to −0.50)−1 (−1.75 to −0.62)−1.25 (−1.62 to −0.62)−0.50 (−0.87 to 0.00)

Results in Myopia and Hyperopia for the 3 Groupsa

ParameterMyopia (n = 6)Hyperopia (n = 11)


Preoperative (Range)6 Months (Range)PaPreoperative (Range)6 Months (Range)Pb
IOL exchange group
  CDVA0.17 (0.07 to 0.47)0.08 (0.03 to 0.34).1160.26 (0.20 to 0.39)0.34 (0.09 to 0.54).398
  SE−8.12 (−9.37 to −3.78)−2.00 (−2.62 to −0.31).0433.12 (1.87 to 4.53)−0.68 (−1.37 to 0.00).005
  Sphere−7.25 (−9.31 to −2.75)−1.50 (−1.75 to 0.50).0423.25 (1.56 to 6.25)0.00 (−0.62 to 1.87).058
  Refractive cylinder−1.00 (−2.50 to −0.62)−2.00 (−2.37 to −0.50).180−0.75 (−2.43 to 0.62)−2.00 (−3.6 to −0.56).397
Piggyback lens group
  CDVA0.14 (−0.04 to 0.93)0.02 (0.00 to 0.38).2730.07 (0.01 to 0.17)0.13 (0.00 to 0.28).034
  SE−2.00 (−3.43 to −0.75)−0.50 (−0.87 to 0.43).1022.25 (1.28 to 2.50)−0.18 (−0.84 to 0.43).001
  Sphere−1.20 (−3.06 to 0.37)0.37 (0.00 to 0.75).3172.87 (1.56 to 3.00)0.50 (−0.25 to 0.87).005
  Refractive cylinder−1.00 (−4.00 to −1.00)−1.00 (−2.00 to −1.00).317−1.00 (−1.50 to −0.50)−1.00 (−1.75 to −0.50).789
LASIK group
  CDVA0.15 (0.04 to 0.19)0.09 (0.00 to 0.16).0410.15 (0.03 to 0.26)0.07 (0.03 to 0.12).086
  SE−1.00 (−1.37 to −0.75)0.00 (0.00 to 0.50).0011.50 (0.75 to 2.50)0.00 (−0.18 to 0.43).003
  Sphere−0.62 (−0.81 to 0.00)0.12 (0.00 to 0.56).0032.00 (1.50 to 2.75)0.12 (0.00 to 0.93).012
  Refractive cylinder−1.37 (−1.81 to −0.75)0.00 (−1.00 to 0.00).004−0.62 (−0.75 to −0.12)−0.62 (−0.75 to −0.12).075