Miscellaneous ECG 2
- Atrial fibrillation with a slow ventricular response
- Digoxin ECG changes
- Premature supraventricular beat (1st complex on ECG)
This ECG demonstrates the typical "reverse check" or "reverse tick" sign seen in the setting of digoxin therapy. Atrial fibrillation with a slow ventricular response is one of the more common rhythms seen in the setting of digoxin toxicity. Click below for a detailed review of digoxin toxicity and ECG findings associated with it.
Related Topic Reviews: Digoxin ECG Changes, Atrial Fibrillation Review, Premature Atrial Contractions